LWH pull rod linear displacement sensor (alias: electronic ruler, resistance ruler, potentiometer, displacement sensor) Principle: Potentiometer principle, all sensors are position measurement type, used in the adjustment system (control system) and measurement system, to directly measure the displacement and length, output DC voltage signal, can also be converted into the standard 0-5V, 0-10V or 4-20mA DC signal through the built-in or external V/A converter module. Can also be remote transmission control requirements. LWH pull rod linear displacement sensor (alias: electronic ruler, resistance ruler, potentiometer, displacement sensor) output displacement variation: 0-100% given input operating voltage (with displacement variation).
Attention:The stroke is from 50mm-1250mm. If you need different lengths of travel, please contact with the supplier. The default output: 0-100% of the power supply voltage value, which is resistance out put, if you need other signal output, such as 4-20mA, 0-5V, 0-10V,and RS485 signal output please purchase the transmission module in the shop or contact with the supplier...
Technical Parameter
Standard Specifications: | brand:Miran |
LWH draw-bar series | 50~110mm | 125~175mm | 200~550mm | 600~1250mm | Stroke Length (mm) 50 75 100 110 125 130 150 175 200 225 250 275 300 325 350 360 375 400 425 450 475 500 550 600 650 700 750 800 850 900 950 1000 1150 1250 |
Linear Precision (±%FS) | ±0.1% | ±0.05% | ±0.05% | ±0.04% |
Resistance (±10%) | 5ΚΩ | 10ΚΩ |
Electrical Stroke | range+3mm |
Resolution | Infinite |
Repeatability Precision | 0.01mm |
Max Speed | 10m/S |
Recommended Current | ≤10mA |
Recommended Voltage | ≤ 36V DC |
Temperature Range | -60℃~+150℃ |
Case Length (A) | Stroke+ 78.5mm |
Mechanical Stroke (B) | Stroke+8mm |
Output | 0~100% × input voltage (change with the movement of the rod) |
insulationresistance(500VDC) | ≥10MΩ |
Maximum Tension | 50 Kg |
Protection Grade | IP 67 |
Very long life | >100*1000000 cycles,>25*1000000 m |
Installation Size (mm)